39
Pre-reset function
Section 11-4
11-4 Pre-reset function
This function is only available on the F3S-TGR-CL_A - models.
The Pre-reset function is an addition to the manual restart function. It can be
used, where the operator doing the restart is not able to see the entire dan-
gerous zone.
!WARNING
The pre-reset pushbutton must be installed in the dangerous zone from where
the operator is able to check that nobody else is in the dangerous zone before
the manual restart function is used. Failure to do so may result in serious
injury.
The time limit between pre-reset and manual reset is 8 sec.
Note •
Pre-reset function sets the F3S-TGR-CL system to manual reset mode.
•
Blanking function can not be selected using pre-reset function.
•
Muting function can not be selected using pre-reset function.
Wiring diagram:
Note
If both inputs Muting A (Green input) and Muting B (Yellow input) loose +24 V,
the F3S-TGR-CL system changes to error condition
Pre - Reset
Reset
SLC
Fence
24 Vdc
Shield
OUT
1
OUT
2
TEST/REST
AR
T
0 Vdc
N.C.
K1
K2
RECEIVER
BROWN BLUE WHITE GREEN YELLOW RED
GRAY PINK
SCH.
PRE-RESET
PIN 2 7 1 3 4 8 5 6
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 39 Dienstag, 4. Oktober 2011 1:32 13