![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286027.webp)
13
Range setting
Section 6-3
6-3
Range setting
Operating range is set using switches 1 and 2 on the transmitter. Please refer
to the table for valid switch position settings.
!WARNING
Never use a long range light curtain for distances under the operating range.
Failure to do so may cause serious injury.
6-4
Selecting Scan Codes
The F3S-TGR-CL receiver and transmitter offer scan code selection to mini-
mize cross talk.
Note
Both receiver and transmitter must be set to the same code.
Example:
Sequence to activate Scan Codes:
1
2
3
TX
1 -> ON
SHORT RANGE SELECTION
2 ->OFF
1 -> OFF LONG RANGE SELECTION
2 -> ON
4
5
RANGE:
LONG RANGE
RANGE:
SHORT RANGE
1
2
3
4
5
TX/RX
Connect white wire
of TX to pink wire of
RX SLC
all LEDs 1 time =
CODE A
all LEDs 2 times =
CODE B
Scan Code A
Scan Code B
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 13 Dienstag, 4. Oktober 2011 1:32 13