Receiver selector switch setting
Firmware 1.2.5
Note
Factory Settings:
RX: All OFF except both DIP switch 8
TX: All OFF except both DIP switch 1
Switch
Status
Function
8
OFF
Manual reset
Single break if SB/DB selected
ON
Automatic reset Double break if SB/DB selected
7
OFF
Refer to CODING section for further information
ON
6
OFF
EDM function disabled
ON
EDM function enabled
5 + 4
1
1. Selector switches 4 and 5 are operational if a muting indicator is connected or both are set to the ON position.
4
5
MUTING and SPECIAL FUNCTIONS
OFF
OFF
MUTING T
OFF
ON
MUTING L
ON
OFF
MUTING X
ON
ON
SPECIAL FUNCTION WITH Switches 1, 2 and 3
MUTING MAPS when MUTING T, L or X are selected on switches 4 and 5
2
2. Selector switches 1, 2 and 3 are operational if a muting function is set and a muting indicator is connected.
3 + 2 + 1
1
2
3
OFF OFF OFF
Muting active over all light curtain
OFF OFF ON
Muting active on module 1,2,3 and 4
OFF ON
OFF Muting active on module 1,2 and 3
OFF ON
ON
Muting active on module 1 and 2
ON
OFF OFF Muting active on module 1
ON
OFF ON
Muting active on module 2
ON
ON
OFF Muting active on module 3
ON
ON
ON
Muting active on module 4
Special functions selection when switches 4 and 5 are both ON
3
3. Selector switches 1, 2 and 3 are operational if selector switches 4 and 5 are in ON position.
3 + 2 + 1
1
2
3
OFF OFF OFF Not supported
OFF OFF ON
OFF ON
OFF
OFF ON
ON
ON
OFF OFF
ON
OFF ON
ON
ON
OFF Pre-Reset mode
ON
ON
ON
Not supported