![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286075.webp)
61
SECTION 16
Diagnostics and Troubleshooting
16-1 Receiver Diagnostic information
16-1-1 Normal operation
16-1-2 Interlock LED indication
If a special function like pre-reset or single/double break is active, the Interlock
LED uses blink codes to display the status.
1 flash per second:
Pre-reset mode active
2 flashes per second:
Waiting for Restart on single/double break function
3 flashes per second:
Normal operation of single/double break function
Disposition of indicator
Name of indicator
Colour
POWER
Green
STATUS
Yellow
GUARD
Green
BREAK
Red
INTERLOCK
Yellow
Description
MACHINE RUN state, OSSDs on
MACHINE STOP state, OSSDs off
Interlock, waiting for restart
Alignment mode - best optical alignment
Short circuit on output
Special function active/special function status, please refer to the chap-
ters
"Setting F3S-TGR-CL features"
on page 9 and
"Control functions"
on
page 30 for details
Floating blanking active, additional object in the protective field
Note
Only on Advanced (A) version
POWER
ST
A
TUS
GUARD
BREAK
INTERLOCK
RX
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 61 Dienstag, 4. Oktober 2011 1:32 13