Cross Talk Mitigation
Section 9-2
The following graphs show the minimum distance d for a operating range R of
up to 20 m:
9-2
Cross Talk Mitigation
To mitigate interference from other light curtains, the F3S-TGR-CL system
has two possible scan codes, A and B. The transmitter and receiver units
must be set to the same scan code for the receiver to enter the MACHINE
RUN state.