![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286028.webp)
14
Selecting Scan Codes
Section 6-4
Wiring diagram when Scan codes are used:
Note
Only available at Active-Active units.
Note
Please make sure that the total cable length between the two units is not
longer than 100 m when coding is used .
Transmitter Scan Code setting, using switches 3 and 4:
Receiver Scan Code setting, using switch 7:
Note
With Active/Passive systems just refer to the Receiver site.
24 Vdc
Shield
PIN 2 7 1 3 4 8 5 6
OUT
1
OUT
2
RL
250mA
max
RL
250mA
max
TEST/REST
AR
T
0 Vdc
N.C.
N.C.
N.C.
RECEIVER
BROWN BLUE WHITE GREEN YELLOW RED
GRAY PINK
SCH.
24 Vdc
Shield
PIN 1 3 2 4
0 Vdc
N.C.
TRANSMITTER
BROWN BLUE WHITE BLACK
SCH.
Note please refer to 6-1-3 Receiver
selector switch setting
SWITCH 3
OFF No code
(exclusion of dip 4)
ON
CODE ON
SWITCH 4
OFF CODE A
ON
CODE B
UPPER SWITCH BANK 7
OFF CODE A
ON
CODE B
LOWER SWITCH BANK 7
OFF No code
(exclusion of dip 7 on upper bank)
ON
Code