![Omron E5AZ User Manual Download Page 145](http://html.mh-extra.com/html/omron/e5az/e5az_user-manual_744338145.webp)
122
Initial Setting Level
Section 5-6
• These parameters set the upper and lower limits of the set points. A set
point can be set within the range defined by the upper and lower limit set
values in the “SP upper limit” and “SP lower limit” parameters. If these
parameters are reset, any set point that is outside of the new range will be
forcibly changed to either the upper limit or the lower limit.
• When the temperature input type and temperature unit have been
changed, the set point upper limit and set point lower limit are forcibly
changed to the upper and lower limits of the sensor.
• During temperature input, the decimal point position depends on the cur-
rently selected sensor, and during analog input it depends on the “deci-
mal point” parameter setting.
Controllers with Thermocouple/Resistance Thermometer Universal-inputs
Controllers with Analog Inputs
Related Parameters
Input type: Page 119, Temperature unit: Page 121 (initial setting level)
• This parameter selects 2-PID control or ON/OFF control.
• The auto-tuning and self-tuning functions can be used in 2-PID control.
sl-h
SP Upper Limit
sl-l
SP Lower Limit
Parameters
Setting range
Unit
Default
Set point
upper limit
Temperature
SP lower limit + 1 to Input
range upper limit
EU
1300
Analog
SP lower limit + 1 to scaling
upper limit
EU
100
Set point
lower limit
Temperature
Input range lower limit to SP
upper limit
−
1
EU
−
200
Analog
Scaling lower limit to SP
upper limit
−
1
EU
0
Parameters
Setting range
Unit
Default
Set point upper limit
SP lower limit + 1 to scaling upper
limit
EU
100
Set point lower limit
Scaling lower limit to SP upper
limit
−
1
EU
0
Function
Setting
See
See
cntl
PID ON/OFF
Setting range
Default
pid
: 2-PID,
onof
: ON/OFF
onof
Function
Setting
■
Summary of Contents for E5AZ
Page 2: ...E5CZ E5CZ U E5AZ E5EZ Digital Temperature Controller User s Manual Produced September 2008 ...
Page 3: ...iv ...
Page 23: ...xxiv ...
Page 53: ...30 Using the Support Software Port Section 2 3 ...
Page 79: ...56 Using HB and HS Alarms Section 3 10 ...
Page 115: ...92 Output Adjustment Functions Section 4 14 ...
Page 173: ...150 Communications Setting Level Section 5 8 ...
Page 205: ...182 Index precautions 22 terminal arrangement 21 terminals 21 ...