![OmniTek Ultra 4K Tool Box User Manual Download Page 82](http://html1.mh-extra.com/html/omnitek/ultra-4k-tool-box/ultra-4k-tool-box_user-manual_739906082.webp)
-------------------------- Signal Analysis: Picture View -----------------------------------
Ultra v2.0a User Guide
J-6
The procedure to follow in setting up the cages is as follows:
To set-up Cages:
Carry out the following steps for each of the Cages you want to set up.
To specify a ‘Standard’ Cage:
Note:
These cages are always positioned centrally about the middle of the screen. Cages that are
displaced from this central position can only be implemented as Variable cages (see below).
1.
Display the
Video
page of the
Configuration
window.
2.
Select the appropriate Standards body from the
drop-down menu offered on the
Default
fixed sizes
line of the
Cages
area of the display.
3.
Select the required screen geometry from the
drop-down menu offered on the first line of the Cage
definition.
Note:
The
Auto
option is not available in the current
version but in future versions will show a cage based
on the Active Format Description embedded in the
selected input.
4.
With the full Cage definition fully displayed,
move the
Dashed
setting to On (
1
) or Off (
0
) as
required. When
Dashed
is set to Off (
0
), the cage
will be displayed as a solid line.
To specify a ‘Variable’ Cage:
1.
Display the
Video
page of the
Configuration
window.
2.
Select
Variable
from the drop-down menu offered on the first line of the Cage definition.
3.
With the full Cage definition fully displayed, set the values you require for the Variable H
and V Sizes and for the Variable H and V Offsets.
The values shown are quoted in terms of
percentages of the width/height of the screen. The
offsets are quoted from the middle of the screen
and refer to the position of the middle of the cage.
Variable
H Size
and
Variable
V Size
can take
values in the range 10 – 100, while
Variable
H
Offset
and
Variable
V Offset
can take values in the
range –50 to 50 (though it should be noted that if
±
Variable
Variable
H Offset
is greater than
(100 –
Variable
H Size
)/2 or ±
Variable
V Offset
is greater than (100 –
Variable
V Size
)/2, part of
the cage will be off the edge of the screen.
4.
Move the
Dashed
setting to On (
1
) or Off (
0
) as
required. When
Dashed
is set to Off (
0
), the cage
will be displayed as a solid line.
Summary of Contents for Ultra 4K Tool Box
Page 1: ...Ultra 4K Tool Box User Guide Version 2 0a August 2015...
Page 8: ...General Ultra v2 0a User Guide...
Page 50: ...General Automated Control Ultra v2 0a User Guide C 6...
Page 52: ...Conversion Facilities Ultra v2 0a User Guide...
Page 62: ...Signal Analysis Ultra v2 0a User Guide...
Page 96: ...Signal Analysis Status Ultra v2 0a User Guide O 4...
Page 98: ...Physical Layer Analysis Ultra v2 0a User Guide...
Page 112: ...Physical Layer Eye Jitter Ultra v2 0a User Guide S 14...
Page 118: ...Generator Ultra v2 0a User Guide...
Page 134: ...Generator Creating Test Patterns W 8 Ultra v2 0a User Guide...
Page 139: ...Ultra v2 0a User Guide...