22. IMAGE QUALITY PROBLEM
Field Service Ver. 1.1 May 2011
356
TROUBLESHOOTING
22.2.12
Printer monocolor: white lines, white bands, colored lines and colored
bands in sub scan direction
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C507DA
White lines
White bands
Colored lines
Colored bands
Step
Section
Check item
Result
Action
1
Image check A white line or black line in sub
scan direction is sharp.
YES
Clean the electrostatic charger wire.
2
When printing thick paper, black
lines appear.
YES
Select [SERVICE MODE]
o
[ADJUST]
o
[THICK MODE] and set
[QUALITY MODE].
3
Imaging unit The surface of the PC drum is
scratched.
YES
Change imaging unit.
4
Dirty on the outside.
YES
Clean.
5
Contact terminals make good con-
nection between each imaging unit
and machine.
NO
Clean contact terminals.
6
Developing bias contact terminal
makes good connection.
NO
Clean contact terminal and check ter-
minal position.
7
PH unit
The surface of the PH window is
dirty.
YES
Clean with cleaning jig.
8
The problem has been eliminated
through the checks of steps up to 7.
NO
Change transfer belt unit.
Change PH unit.
d-Color MF2400
Summary of Contents for PF-P09
Page 1: ...SERVICE MANUAL Color Printer d Color MF2400 PF P09 Code Y113750 1...
Page 4: ...ii Blank Page...
Page 27: ...SERVICE MANUAL Color Printer d Color MF2400 Code Y113750 1...
Page 436: ...SERVICE MANUAL Color Printer Code Y113750 1 SERVICE MANUAL PF P09...
Page 457: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 12 2011 1ST EDITION 457 Y113750 1...