13. SERVICE MODE
Field Service Ver. 1.1 May 2011
146
ADJUSTMENT
/ SETTING
13.4.16
MAIN SCAN SCALE - MAIN SCAN PAGE
A. Use
• Prints the test pattern used for the main scan adjustment.
B. Procedure
1.
Call the Service Mode to the display.
2.
Select [ADJUST]
o
[MAIN SCAN SCALE]
o
[MAIN SCAN PAGE], and press the
Select key.
3.
Select [PRINT], and press the Select key.
4.
The test pattern is output.
13.4.17
MAIN SCAN SCALE - SCAN ADJUST VALUE
A. Use
• Adjusts magnification in the main scan direction.
• Use when replacing the PH unit.
• This adjustment is necessary when the adjustment values are cleared due to the
replacement of the EEPROM on the print control board or other reasons.
B. Procedure
1.
Select [ADJUST]
o
[MAIN SCAN SCALE]
o
[MAIN SCAN PAGE] to print the test pat-
tern.