Field Service Ver. 1.1 May 2011
14. SOFT SWITCH SET
225
ADJUSTMENT
/ SETTING
14.3.17
SOFT SWITCH: #17
• T5: 60 ± 5 sec. in ITU-T standard
Bit No.
Designation
Function
Initial
setting
Bit
HEX
8
Reserved
Reserved
0
0
7
0
6
CED frequency
0: 2100 Hz
0
1: 1100 Hz
5
Pause between off
hook and CED signal
0
4
0
0
3
0
2
Inactivity timer [T5]
0
1
0
Time (T)
T=1.8 sec
to 2.5 sec
T+ 100 ms T+ 200 ms T+ 300 ms
Bit No. 5
0
0
0
0
Bit No. 4
0
0
1
1
Bit No. 3
0
1
0
1
Time (T) T+ 400 ms T+ 500 ms T+ 600 ms T+ 700 ms
Bit No. 5
1
1
1
1
Bit No. 4
0
0
1
1
Bit No. 3
0
1
0
1
Description
T5
T5 + 20 sec T5 + 40 sec T5 + 60 sec
Bit No. 2
0
0
1
1
Bit No. 1
0
1
0
1