CS9350 User’s Guide
7-187
NOTE
[****] of the error display indicates the ink color that is subject to warning.
28
Color measuring mode error
(Command)
The parameters of the
command sent from RIP
software are abnormal.
Check the settings of color
calibration or color profiling
of the RIP software.
—
29
Color measuring mode error
(Media End)
The media has run out while
printing or measuring the
color target.
Load new media and start
printing and measuring the
color target again.
4.5 Using
spectrophotometer
30
Color measuring mode error
(Cover Open)
Cover(s) opened while
measuring the color target.
Close the front cover and the
maintenance covers on both
sides of the printer.
3.4 Loading
media
6.2.4 Cleaning
the cleaning wiper
31
Measurement Error
(Lever Lifted)
The media loading lever is
raised while printing or
measuring the color target.
Printing or measuring is
cancelled. Start printing and
measuring the color target
again.
4.5 Using
spectrophotometer
32
Measurement Error
(Communication)
A communication error
occurred while printing or
measuring the color target.
Check the communication
requirements between the
printer and your PC.
Connecting the
printer to PC
33
Measurement Error
(Instrument)
A communication error with
spectrophotometer occurred
while measuring the color
target.
Check the connection
between the printer and
spectrophotometer.
4.5 Using
spectrophotometer
34
Measurement Error
(Cancelled)
Printing or measuring the
color target has been
cancelled from the operation
panel or the RIP software.
Start printing and measuring
the color target again.
4.5 Using
spectrophotometer
35
Measurement Error
(White Calibration)
White calibration has failed.
•Open the maintenance cover
on the left side of the
printer and install the white
reference plate correctly.
•When the white reference
plate is contaminated,
apply a damp and tightly
squeezed soft cloth to clean
it.
•Start printing and measuring
the color target again.
•If you still have trouble,
contact your local Océ
representative.
4.5 Using
spectrophotometer
36
Measurement Error
(Illegal Operation)
Colorimeter has been
installed forcibly without
following the proper color
measurement procedure.
Remove the colorimeter.
4.5 Using
spectrophotometer
N°
Display
Description
Remedy
Reference
Summary of Contents for CS9350
Page 1: ...Oc CS9350 Eco Solvent User s Guide AP 40801_1 0...
Page 2: ......
Page 10: ...User s Guide CS9350 10 AP 40801 Revision 1 0...
Page 17: ...CS9350 User s Guide 1 17 2 Rear N Types of warning labels 1 2 2...
Page 26: ...CS9350 User s Guide 2 26...
Page 100: ...CS9350 User s Guide 4 100...
Page 176: ...CS9350 User s Guide 6 176...
Page 192: ...CS9350 User s Guide 7 192...