Screen Descriptions
14-4
Part 7440274
2017 Nordson Corporation
Faults & Warnings 1 and 2
Faults & Warnings 1
The
Faults & Warnings 1
Screen allows the operator to determine the cause
of a fault or warning. Operators may be informed of the following faults and
warnings:
Dispense Motion Fault
indicates there is a problem with the motion of
the metering rod during the dispense phase. Ensure the position sensor
is operating correctly. Also observe the function of the dispense valve
and affiliated components. Ensure there is adequate system air and
material pressure.
Emergency Stop
indicates that the
Emergency Stop
button on the
control panel has been depressed. To reset the system, release the
Emergency Stop
button and press the
Reset Faults
navigation button on
the
Faults & Warnings 1 and 2
Screen.
Interlock Dispense
indicates a fault with the safety interlock.
Material Temperature
indicates that the material temperature is outside
the specified range.
Position Switch Stuck
indicates the position switch is stuck and needs to
be serviced to continue production.
Purge Fault
indicates that the purge timer has expired with no purge
shot taken.
Purge Warning
is an indicator denoting the commencement of the purge
process.
Reload Motion Fault
indicates there is a problem with the motion of the
metering rod during system reload. Ensure nothing is in the way of the
position sensor.