Meter Connections
3-3
Part 7440274
2017 Nordson Corporation
2 Pro
−
Meter V2K Shown With Material, Air, And Other Connections
Item
Description
1
Ball valve
−
serves as an inlet valve
2
Gravity tank (if equipped)
−
supplies material to the Pro
−
Meter V2K
3
Metering cartridge assembly discharge port
−
routes material to dispense valve
4
Pressure transducer (if equipped)
−
records system pressure
5
Metering cartridge assembly bleed valve
−
allows air to be bleed from metering cartridge assembly
6
Weep plug
−
plug to inspect condition of metering cartridge assembly primary seal. Material ob-
served from the weep plug denotes metering cartridge assembly primary seal failure.
7
Metering cylinder housing oil cup
−
allows Seal Sav’r oil to be added to the metering cylinder
housing.
8
Micro PLC
−
serves as the system logic controller and directly interacts with HMI control panel
9
Power supply assembly
−
contains power switch, power supply, power connections, and filter reg-
ulator assembly
10
Pneumatic valve manifold
−
contains air solenoids that routes air to system components
11
Air actuator flow control valve
−
meters air actuator air flow to control dispense and reload speed
2
1
3
4
5
8
9
10
11
6
7
Figure 3-2