Removal and Installation
10-3
Part 7440274
2017 Nordson Corporation
CAUTION:
Utilize a small screwdriver to remove green terminal blocks.
Remove options harness block to access green terminal block located
on the side of the micro PLC closest the pneumatic valve manifold. See
Be careful not to kink or otherwise damage electrical wiring harness.
5. Remove cap screws securing air valve control shelf to strike end
bracket.
6. Carefully pivot air valve control shelf upwards.
7. Remove limit switch mount from metering cylinder housing (if
necessary). To remove limit switch mount, proceed as follows:
Remove limit switch mount (1) from metering cylinder housing (2).
1
2
Figure 10-11 Limit Switch Mount Removal