Disassembly and Assembly
11-11
Part 7440274
2017 Nordson Corporation
Assembly
Assembly is in the reverse order of disassembly. Note the following:
Refer to
Metering Cartridge Assembly Service Kit (page 15
detailed listing of available metering cartridge assembly service kits.
Hand tighten tie rods to metering cylinder body so that they are snug.
Loosely install nuts (15) and tighten to 13.5 N
m (10.0 ft
−
lb). See Figure
11-59.
Hand tighten bearing retainer until it is snug.
CAUTION:
Do not reuse bearings, O
−
rings, caps, Parbak rings, and seals.
Do not utilize sharp or pointed tools to install O
−
rings and seals.
Apply Chevron
Petrolatum Snow to bearings, O
−
rings, caps, Parbak
rings, and seals.
Be sure to correctly install the seals into the lantern ring.
Place lantern ring in an arbor press and carefully install seal.