Removal and Installation
10-19
Part 7440274
2017 Nordson Corporation
Limit Switch
At Metering Cylinder Housing
Removal
WARNING:
Relieve system air pressure, material pressure, and disconnect power
prior to servicing Pro
−
Meter V2K components. Refer to
Preparation For Maintenance And Service (page 8
information.
Allow only qualified personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
Clean any material that has spilled. Be sure to follow all applicable
safety and environmental guidelines when cleaning spilled material.
Refer to
1. Remove the secondary cover (2) from the primary cover (1).
CAUTION:
Utilize hand pressure to lift secondary cover from primary cover
Be sure not to damage secondary cover mounting tabs.
1
2
Figure 10-27 Secondary Cover Removal From Primary Cover
2. Remove socket head cap screws securing primary cover to primary
cover bracket (LH/RH).
3. Remove primary cover from dispense system.