TECHNICAL CHARACTERISTICS OF THE PRODUCT
WARNINGS:
•
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S .p .A. reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality .
Product Type
S4BAR is an electromechanical road barrier for residential use. Controls opening and closing of
an access point with a maximum width of 4 m. Complete with electronic control unit
Maximum torque on start-up
100 Nm
Nominal torque
25 Nm
Maximum operating
cycle frequency
100 (80 with XBA4 accesory) cycles / hour
at nominal torque *
Maximum continuous operating
10 (8 with XBA4 accesory) minutes
time at nominal torque **
Opening time
≥ 4 s (>5s with XBA4 accesory)
Durability
between 80,000 and 500,000 manoeuvre cycles according to the conditions stated in Table 2
Peak power supply
230 Vac (50/60Hz)
Peak power absorption on start-up
300W
Maximum power at nominal torque
200 W
Insulation class
I
Emergency power supply
Yes (with PS124 accessory)
Courtesy light
With XBA7 LED flashing accessory
Flashing light output
For 1 flashing light LUCYB, MLB or MLBT (12 V - 21 W lamp)
BLUEBUS output
1 output with maximum load of 12 Bluebus units
STOP Input
For normally closed, normally open or 8.2 k
Ω
; constant resistance contacts in self-learning mode
(a change from the memorised state prompts the “STOP” command)
S.S. input
For normally open contacts (closure of the contact prompts the Step by Step command)
OPEN Input
For normally open contacts (closure of the contact prompts the OPEN command)
CLOSE Input
For normally open contacts (closure of the contact prompts the CLOSE command)
Radio AERIAL input
52
Ω
for RG58 or similar type cable
Radio connector
SM connector for receiver types SMXI, SMXIS or OXI, OXIT and OXIFM
Programmable functions
8 ON-OFF type functions and 8 adjustable functions (see tables 6 and 7)
Self-learning of devices connected to the BlueBus output. Self-learning of “STOP”
Functions in self-learning mode type devices (contacts NO, NC or 8,2K
Ω
). resistance).
Learning of pole opening and closing positions and calculation of the points of deceleration and
partial opening
Operating temperature
-20° C ... +50° C
Protection rating
IP 44
Dimensions
1146 x 330 h 179,5; pole: minimum 2 m - maximum 4 m
Weight
35 kg
Note
:
(
*
) At 50°C the maximum operating frequency is 40 cycles/hour
(
**
) At 50°C the maximum continuous operating time is 5 minutes.
Summary of Contents for S4BAR
Page 2: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 100: ......
Page 120: ......
Page 140: ......
Page 143: ...I I 1 A B C B 330 mm 2 179 5 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c...
Page 144: ...II II 5 A B C 1 2 4...
Page 145: ...III III 9 10 90 6 A C B 7 8 B A...
Page 146: ...IV IV 14 A B 15 A B 11 A B 12 13 A B...
Page 147: ...V V 16 A B 17 18...
Page 148: ...VI VI 20 180 21 C C A B 1cm 1cm 19 A C B...
Page 149: ...VII VII 22 23 26 L N 24 1 2 25...
Page 151: ...IX 30 A A B STOP 31 A B...
Page 152: ...X 32 A B C D STOP 33 A B 34...
Page 154: ...XII 300 200 700 500 39 300 200 700 500 150 40 41...
Page 155: ...a c d e b F2 F1 42 43 XIII...
Page 156: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g...
Page 157: ......
Page 158: ......
Page 159: ......