EN
English –
13
TABLE 15 - Button LEDs on control unit
Led 1
Description
Off
During normal operation, indicates “Automatic closure” not active .
On
During normal operation, indicates “Automatic closure” active .
Flashes
• Programming of functions in progress .
• If this flashes together with L2 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash
After control unit start-up, it indicates a memory error regarding the devices connected . At the same time, the “Bluebus” led emits
a diagnostic signal: 5 flashes - pause of 1 second - 5 flashes. In this case the learning phase for connected devices must be
performed (see paragraph 4 .4) .
Led 2
Description
Off
During normal operation, indicates “Re-close after photo” not active .
On
During normal operation, indicates “Re-close after photo” active .
Flashes
• Programming of functions in progress .
• If this flashes together with L1 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash
After control unit start-up, it indicates a memory error regarding the positions . At the same time, the “Bluebus” led emits a diagnostic
signal: 5 flashes - pause of 1 second - 5 flashes. In this case the learning phase for the Opening and Closing positions must be
performed (see paragraph 4 .5) .
Led 3
Description
Off
During normal operation, indicates “Re-close after photo” not active .
On
During normal operation, indicates “Re-close after photo” active .
Flashes
• Programming of functions in progress
• If this flashes together with L1 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash
After control unit start-up, it indicates a memory error regarding the parameters and configurations . At the same time, the “Bluebus” led
emits a diagnostic signal: 5 flashes - pause of 1 second - 5 flashes. In this case the memory must be deleted (see paragraph 8.1), and
also the learnt connected devices (see paragraph 4 .4) and learnt Opening and Closing positions (see paragraph 4 .5) .
Led 4
Description
Off
During normal operation, indicates “Stand-BY” not active .
On
During normal operation, indicates “Stand-BY” active .
Flashes
• Programming of functions in progress
• If this flashes together with L3 this indicates that the pole opening and closing learning phase must be performed (see paragraph 4.5).
Led 5
Description
Off
During normal operation, indicates “Short deceleration” active .
On
During normal operation, indicates “Long deceleration” active .
Flashes
Programming of functions in progress .
Led 6
Description
Off
During normal operation, indicates “Pre-flash” not active.
On
During normal operation, indicates “Pre-flash” active.
Flashes
Programming of functions in progress .
Led 7
Description
Off
During normal operation, indicates “Current sensitivity control” not active .
On
During normal operation, indicates “Current sensitivity control” active .
Flashes
Programming of functions in progress .
TABLE 14 - Terminal LEDs on control unit
Bluebus LED
Cause
Solution
Off
Fault
Check for presence of the power supply; check that the
fuses are not blown; in this case, identify the cause of
the fault and then replace with versions with the same
specifications.
On
Serious fault
This indicates a serious fault; try switching off the control
unit for a few seconds; if the condition persists there is a
fault and the electronic board needs to be replaced .
1 flash per second
All OK
Normal operation of control unit
2 quick flashes
Input status variation
A variation to the status of the inputs SS, STOP, OPEN,
CLOSE, activation of the photocells, or when the radio
transmitter is used, is normal .
Series of flashes separated by a pause
Various
This is the same signal of 1 second as on the flashing
light
(See table 15)
Led STOP
Cause
Solution
Off
STOP input activation
Check the device connected to the STOP input
On
All OK
Ingresso STOP attivo
S.S. LED
Cause
Solution
Off
All OK
S .S . Input not active
On
S .S . input activation
Normal if the device connected to the S .S . input is active
OPEN LED
Cause
Solution
Off
All OK
OPEN input not active
On
OPEN input activation
Normal if the device connected to the OPEN input is active
CLOSE LED
Cause
Solution
Off
All OK
CLOSE input not active
On
CLOSE input activation
Normal if the device connected to the CLOSE input is
active
Summary of Contents for S4BAR
Page 2: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 100: ......
Page 120: ......
Page 140: ......
Page 143: ...I I 1 A B C B 330 mm 2 179 5 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c...
Page 144: ...II II 5 A B C 1 2 4...
Page 145: ...III III 9 10 90 6 A C B 7 8 B A...
Page 146: ...IV IV 14 A B 15 A B 11 A B 12 13 A B...
Page 147: ...V V 16 A B 17 18...
Page 148: ...VI VI 20 180 21 C C A B 1cm 1cm 19 A C B...
Page 149: ...VII VII 22 23 26 L N 24 1 2 25...
Page 151: ...IX 30 A A B STOP 31 A B...
Page 152: ...X 32 A B C D STOP 33 A B 34...
Page 154: ...XII 300 200 700 500 39 300 200 700 500 150 40 41...
Page 155: ...a c d e b F2 F1 42 43 XIII...
Page 156: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g...
Page 157: ......
Page 158: ......
Page 159: ......