WARNINGS:
- Do not set an excessively high value for the “motor force” as this may impair operation of the safety system or damage the pole;
- If the “Motor force control” is used in support of the system for impact force reduction, after each adjustment the force measurement procedure must be performed, as envisaged
by standard EN 12445 .
- Wear and atmospheric conditions influence movement of the pole; motor force settings should be checked periodically.
The type of fault that has occurred in
the last 8 manoeuvres can be establi-
shed (see: paragraph 8 .2 - malfunction
event log and Table 14) .
A detailed log can be stored of all
events on S4BAR (and other devices
connected on the network) by con-
necting the Oview programmer
L8
L1
L2
L3
L4
L5
L6
L7
L8
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
List of
faults
TABLE 7 - Second level functions
Input LED
Parameter
LED (level)
Value
Description
L2
L1
L2
L3
L4
L5
L6
L7
L8
Open – stop – close - stop
Open – stop – close - open
Open – close – open - close
Apartment block (more than 2 sec . generates Stop)
Apartment block 2 (less than 2 sec . generates partial opening) .
Step by step 2
Hold-to-run
Opening in semi-automatic mode, closing in dead man mode
Sets the sequence of commands as-
sociated with the input or the radio
control: “Step by step” .
Function
Step by
step
L1
L1
L2
L3
L4
L5
L6
L7
L8
5 seconds
10 seconds
20 seconds
40 seconds
60 seconds
80 seconds
120 seconds
200 seconds
Sets the pause time, i .e . the time that
passes between the end of an ope-
ning manoeuvre and the start of an
automatic closing manoeuvre
This parameter is only effective if the
“automatic Closure” is active .
Time
Pause
L3
L1
L2
L3
L4
L5
L6
L7
L8
Speed 1 (30% - slow)
Speed 2 (47%)
Speed 3 (65%)
Speed 4 (82%)
Speed 5 (100%) - fast
Open V3, Close V2
Open V4, Close V3
Open V5, Close V4
Sets the motor speed during normal
travel .
Speed
Motor
L4
L1
L2
L3
L4
L5
L6
L7
L8
Pole Open Indicator Function (24 V - 10 W)
Active if pole closed (24 V - 10 W)
Active if pole open(24 V - 10 W)
Flashing light(12 V - 21 W)
Flashing light for pole lights (24 V - 10 W) - always flashes
Electric lock(24 V - 10 W)
Suction cup(24 V - 10 W)
Maintenance indicator (24 V - 10 W)
Selects the type of device connected
to the FLASH output .
Important!
– If the programmed set-
ting is modified, check the type of vol-
tage of the new device connected to
the FLASH terminal and ensure that it
corresponds to the type of voltage of
the selected programming level .
Output
FLASH
L5
L1
L2
L3
L4
L5
L6
L7
L8
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force 8 (high)
Adjusts the motor force control sy-
stem to adapt it to the weight of the
pole during the opening manoeuvre
and consequently the sensitivity of
obstacle detection .
Note
– The force is acquired auto-
matically during execution of the first
two manoeuvres .
Motor
force on
opening
L6
L1
L2
L3
L4
L5
L6
L7
L8
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force 8 (high)
Adjusts the motor force control sy-
stem to adapt it to the weight of the
pole during the closing manoeuvre
and consequently the sensitivity of
obstacle detection .
Note
– The force is acquired automa-
tically during execution of the first two
manoeuvres .
Motor
force on
closure
L7
L1
L2
L3
L4
L5
L6
L7
L8
2500
5000
10000
15000
20000
30000
40000
50000
When the FLASH output is program-
med as a maintenance indicator: this
sets the maximum number of mano-
euvres to be performed, after which
the signal is sent to notify of the need
for automation maintenance .
Mainte-
nance
warning
Summary of Contents for S4BAR
Page 2: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 100: ......
Page 120: ......
Page 140: ......
Page 143: ...I I 1 A B C B 330 mm 2 179 5 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c...
Page 144: ...II II 5 A B C 1 2 4...
Page 145: ...III III 9 10 90 6 A C B 7 8 B A...
Page 146: ...IV IV 14 A B 15 A B 11 A B 12 13 A B...
Page 147: ...V V 16 A B 17 18...
Page 148: ...VI VI 20 180 21 C C A B 1cm 1cm 19 A C B...
Page 149: ...VII VII 22 23 26 L N 24 1 2 25...
Page 151: ...IX 30 A A B STOP 31 A B...
Page 152: ...X 32 A B C D STOP 33 A B 34...
Page 154: ...XII 300 200 700 500 39 300 200 700 500 150 40 41...
Page 155: ...a c d e b F2 F1 42 43 XIII...
Page 156: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g...
Page 157: ......
Page 158: ......
Page 159: ......