Front panel
SMO 10
4
Display
Hotwatertemperature
Left keypad
Offset heating
curve
Display
First row:
Compressor symbol
A
together with a compressor symbol is
shown when step 1 is operational.
B
together with a compressor symbol is
shown when step 2 is operational.
Only a compressor symbol indicates that the compres-
sor will start, but is blocked as an internal start condi-
tion in FIGHTER 2010 / 2005 has not been met, e.g.
stop temperature.
Supplement symbol
Shown when additional heat is connected.
The line indicates which power step/steps
are currently connected.
Only shown when the immersion heater is
connected.
Power step
I
is connected.
Power step
II
is connected.
Power step
III
is connected.
Only lightening is shown with hot water
production.
Layout
B
C
Switch
A
D
Right
keypad
A B
E
B
Explanation
I II III
Switch
with three positions 1 - 0 -
:
1
Normal mode. All control functions connected.
0
The system is completely switched off.
Standby. This position is used in the event
of operating disturbances. Additional heat
output is limited depending on the chosen
connection option. See section Dealing with
malfunctions.
NOTE! With outdoor temper-
atures below 0°C there is a risk of freez-
ing.
A
Summary of Contents for SMO 10
Page 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...
Page 2: ......
Page 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...
Page 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...
Page 58: ...SMO 10 56...
Page 59: ......