A B
I II III
5 0 . 0 ° C
H o t w a t e r t e m p .
1.0
13.43
A B
Control
SMO 10
26
Changing a parameter (value):
■
Access the required menu.
■
Press the enter button, the numerical value starts to
flash
■
Increase or decrease the value with the Plus/Minus
buttons.
■
Confirm by pressing the enter button.
■
Menu 1.0 is automatically displayed again 30 min-
utes after pressing the last button.
Example
Changing the curve slope, menu 2.1.
■
The starting point is menu 1.0.
■
Press the plus button to move to menu 2.0.
■
Press the enter button to move to menu 2.1.
■
Press the enter button to allow the value to be
changed.
■
Change the value by pressing the plus or minus
buttons.
■
Confirm the chosen value by pressing the enter but-
ton.
■
Press the minus button to move to menu 2.9.
■
Press the enter button to move to menu 2.0.
■
Press the minus button to move to menu 1.0.
The menu tree shows all the menus. Three different
menu types can be chosen.
Normal, covers the normal user's needs.
Extended, shows all menus except the service
menus.
Service, shows all menus, returns to normal 30
minutes after the last button was pressed.
Changing of menu type is done from menu 8.1.1
Information is presented on the display about the status
of the heat pump and the electric boiler. Menu 1.0 is nor-
mally shown on the display screen. The Plus and Minus
buttons and the Enter button are used to scroll through
the menu system as well as to change the set value in
some menus.
The Plus button is used to move for-
ward to the next menu on the current
menu level and to increase the value of
the parameter in menus where this is
possible
The Minus button is used to move back
to the previous menu on the current
menu level and to decrease value of
the parameter in menus where this is
possible.
The enter button is used to select sub-
menus of the current menu, to permit
parameters to be changed and confirm
any changes to parameters. When the
menu number ends with a zero this
indicates there is a sub-menu.
N
U
S
General
Changing parameters
To quickly return to the main menu from sub-menus
press the following:
■
Operating mode button
■
Enter
Quick movement
NOTE!
Ensure the operating mode is not
changed during quick movement
Menu name
Menu number
Key lock
Clock
Symbols
Value of the
current parameter
A key lock can be activated in the main menus by
simultaneously pressing the Plus and the Minus but-
tons. The key symbol will then be shown on the dis-
play. The same procedure is used to deactivate the
key lock.
Key lock
Summary of Contents for SMO 10
Page 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...
Page 2: ......
Page 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...
Page 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...
Page 58: ...SMO 10 56...
Page 59: ......