Control
36
SMO 10
Menu 7.1 Date
The current date is set.
Menu 7.3.0 Temp set back
Settings, e.g. for night reduction can be selected in the
sub-menus to this menu.
2 0 0 3 - 0 9 - 2 4
D a t e
7 . 1
T e m p s e t b a c k
7 . 3 . 0
Menu 7.3.1 Set back time
The time for the day change, e.g. night reduction is
chosen here.
2 2 : 0 0 - 0 4 : 3 0
S e t b a c k t i m e
7 . 3 . 1
Menu 7.3.2 Set back temp +/-
Changes to the flow temperature with a day change,
e.g. night reduction are set here. The value is
adjustable between -25 and +25 °C.
0 ° C
S e t b a c k t e m p + / -
7 . 3 . 2
Menu 7.3.3 Return
Pressing the Enter button returns you to menu 7.3.
R e t u r n
7 . 3 . 3
Menu 7.2 Time
Here the current time is set.
1 3 : 3 9
T i m e
7 . 2
Time and Date
Menu 7.4.0 Extra hot water
Settings are made in the sub-menus of this menu
when extra hot water is required on a specific day.
E x t r a h o t w a t e r
7 . 4 . 0
Menu 7.4.1 — 7.4.7 Extra HW Monday - Sunday
Here you select the period for respective days when
extra hot water should be activated. Hours and min-
utes for both start and stop are shown Equal values or
the stop time before the start time mean that extra hot
water is not activated.
0 3 : 3 0 – 0 6 : 1 5
E x t r a H W M o n d a y
7 . 4 . 1
Menu 7.4.8 Back
Pressing the enter button returns you to menu 7.4.0
R e t u r n
7 . 4 . 8
Menu 7.5 Back
Pressing the Enter button returns you to menu 7.0.
R e t u r n
7 . 5
U
U
N
N
U
U
U
Summary of Contents for SMO 10
Page 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...
Page 2: ......
Page 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...
Page 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...
Page 58: ...SMO 10 56...
Page 59: ......