Electrical connection
SMO 10
14
For communications between SMO 10 and FIGHTER
2010 / 2005 use the supplied modular cable of 15 m.
The modular cable is connected between SMO 10
position (4) and FIGHTER 2010 / 2005 position (44),
see the Installation and Maintenance Instruction.
Routing of the modular cable in FIGHTER 2010 / 2005
should be done from below in the cable glands on left-
hand side of the heat pump, seen from the front.
LEK
44
FIGHTER 2010 / 2005
SMO 10
Modular cable between SMO 10 and one FIGHTER 2010 / 2005
4
LEK
29
4
SMO 10
FIGHTER 2010
44
FIGHTER 2010/2005
NOTE!
The modular cables should be routed
separately from power cables when
cable routing.