Service menus
44
SMO 10
Operating settings
Menu 9.3.8.0 Testmode
Only for service personnel.
T e s t m o d e
9 . 3 . 8 . 0
Menu 9.3.9 Operating mode
Describes the current operating status of SMO 10 and
FIGHTER 2010 / 2005.
Shutoff:
Addition heat and the heat pump are shutoff
due to an alarm.
Switch mode:
FIGHTER 2010 / 2005 produces all
heat and switches if necessary between hot water and
the heating system.
Combi mode:
Due to the large heating requirement,
the immersion heater is used for hot water and
FIGHTER 2010 / 2005 produces heating. The addi-
tional heat helps if necessary with heating production.
Hot water:
Only hot water is produced. This is done
with FIGHTER 2010 / 2005.
Addition:
FIGHTER 2010 / 2005 is switched off and
both hot water and heating is produced by the addi-
tional heat.
O p e r a t i n g m o d e
9 . 3 . 9
S
S
Menu 9.3.5.0 Floor drying
Settings for the floor drying program are made in the
sub-menus to this menu.
F l o o r d r y i n g
9 . 3 . 5 . 0
Menu 9.3.5.1 Floor drying
This sub-menu is used to select whether the floor dry-
ing program should be On or Off. After time period 1
switching to time period 2 then return to normal set-
tings.
O f f
F l o o r d r y i n g
9 . 3 . 5 . 1
Menu 9.3.5.2 Numb. of days per. 1
Selection of the number of days in period 1.
The value is adjustable between 1 to 5 days.
3 D a y s
N u m b . o f d a y s p e r . 1
9 . 3 . 5 . 2
Menu 9.3.5.3 Temp per. 1
Selection of the flow temperature in period 1.
The value is adjustable between 15 and 50 °C.
2 5 ° C
T e m p p e r . 1
9 . 3 . 5 . 3
S
S
S
S
Menu 9.3.5.4 Numb. of days per. 2
Selection of the number of days in period 2.
The value is adjustable between 1 to 5 days.
1 D a y
N u m b . o f d a y s p e r . 2
9 . 3 . 5 . 4
S
Menu 9.3.5.5 Temp per. 2
Selection of the flow temperature in period 2.
The value is adjustable between 15 and 50 °C.
4 0 ° C
T e m p p e r . 2
9 . 3 . 5 . 5
Menu 9.3.5.6 Return
Pressing the Enter button returns you to menu 9.3.5.0.
R e t u r n
9 . 3 . 5 . 6
S
S
Menu 9.3.6 Remove alarms
Resetting alarms in SMO 10.
N o
R e m o v e a l a r m s
9 . 3 . 6
Menu 9.3.7 Factory setting
Return to the factory settings in SMO 10, Yes or No.
N o
F a c t o r y s e t t i n g
9 . 3 . 7
S
S
Summary of Contents for SMO 10
Page 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...
Page 2: ......
Page 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...
Page 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...
Page 58: ...SMO 10 56...
Page 59: ......