Control
34
SMO 10
Menu 5.1 Select pump
The FIGHTER 2010 / 2005 you wish to read is select-
ed here. The selected FIGHTER 2010 / 2005 is shown
in the following menus to the right.
Heat pump
1
S e l e c t p u m p
5 . 1
Menu 5.2 HP operating mode
The operating mode that the FIGHTER 2010 / 2005 is
in is shown here, alternatively which alarm that is acti-
vated (corresponds to channel 00 in FIGHTER 2010 /
2005). In the event of an alarm FIGHTER 2010 / 2005
can be restarted with the Enter button.
H P o p e r a t i n g m o d e
1
5 . 2
Menu 5.3 Compressor status
Shows the compressor status for FIGHTER 2010 /
2005 (corresponds to channel 27 in FIGHTER 2010 /
2005).
Wait signifies that the compressor starts as soon as
the time condition in FIGHTER 2010 / 2005 permits.
Stopped means the compressor is at a stand still.
Compr. step A means that the compressor runs at
step A, low output mode. (only FIGHTER 2010)
Compr. step B means that the compressor runs at
step B, high output mode. (only FIGHTER 2010)
C o m p r e s s o r s t a t u s
1
5 . 3
Menu 5.4 Minutes to start
The time to compressor start in FIGHTER 2010 / 2005
is shown in this menu.
M i n u t e s t o s t a r t
1
5 . 4
Menu 5.5 Starts count A
The accumulated number of starts with compressor
step 1 in FIGHTER 2010. (Does not apply to FIGHTER
2005.)
8 2
S t a r t s c o u n t A
5 . 5
Menu 5.6 Start count B
The accumulated number of starts with compressor
step 2 in FIGHTER 2010 / 2005.
4 8
S t a r t s c o u n t B
1
5 . 6
Menu 5.7 Acc. run time A
The accumulated time that the compressor step 1 has
been used on FIGHTER 2010 is shown here. (Does not
apply to FIGHTER 2005.)
1 1 2 h
A c c . r u n t i m e A
1
5 . 7
Menu 5.8 Acc. run time B
The accumulated time that the compressor step 2 has
been used on FIGHTER 2010 / 2005 is shown here.
8 5 h
A c c . r u n t i m e B
1
5 . 8
N
N
N
N
U
U
U
U
Menu 5.10 Vapor temperature
In this menu the evaporator temperature in FIGHTER
2010 / 2005 is shown.
- 2 . 1 ° C
V a p o r t e m p e r a t u r e 1
5 . 1 0
Menu 5.9 Air temperature
The outdoor air temperature that FIGHTER 2010 /
2005 measures is shown in this menu.
5 . 0 ° C
A i r t e m p e r a t u r e
1
5 . 9
U
U