Service menus
42
SMO 10
Add heat settings
Menu 9.2.7 Shunt Amplification 2
Applies to a possible shunt 2 (SV2). For example, 2
degree difference and 2 in amplification gives 4
sec/min in control of the shunt. This function compen-
sates for the speed variation found on different shunt
motors that may be installed. The value is adjustable
between 1 and 10 (accessories are needed).
2
S h u n t A m p l i f i c a t i o n 2
9 . 2 . 7
S
Menu 9.2.4 Reg. amplification
Default setting is 0, must not be changed in SMO.
Min and max limits are 0 to 100 degree min. per
degree.
Menu 9.2.3 Docking type
The current docking option is set here:
■
VVM
■
SMO Oil boiler
■
SMO Immersion heater after shuttle valve
■
SMO Exhaust air heat pump
■
SMO Immersion heater before shuttle valve
■
Heater
SMO 10 Oilburner
D o c k i n g t y p e
9 . 2 . 3
0
R e g . a m p l i f i c a t i o n
9 . 2 . 4
Menu 9.2.5 Integrator time
The number of degree-minutes that run per step after
additional heat has been engaged is set here.
The value is adjustable between 10 and 100 degree-
minutes.
1 0 0
I n t e g r a t o r t i m e
9 . 2 . 5
Menu 9.2.6 Shunt Amplification
Applies to shunt 1 (SV1). For example, A 2 degree dif-
ference and 2 in amplification gives 4 sec/min in con-
trol of the shunt. The value is adjustable between 1
and 10.
2
S h u n t A m p l i f i c a t i o n
9 . 2 . 6
S
S
S
S
Menu 9.2.1 Start add. heat.
Degree minute deficiency before additional heat is
engaged. The value is adjustable between -1000 and
-30.
- 4 0 0
S t a r t a d d . h e a t .
9 . 2 . 1
Menu 9.2.2 Time factor
The time factor of the immersion heater since first
start up is shown here. The value is saved in the
microprocessor and thus is not reset even when boiler
is switched off using the main power switch.
1 8
T i m e f a c t o r
9 . 2 . 2
S
S
Menu 9.2.0 Add heat settings
Settings concerning additional heat and the shunt in
SMO 10 and any extra shunt are made in the sub-
menus to this.
A d d h e a t s e t t i n g s
9 . 2 . 0
S