Control
38
SMO 10
Menu 8.2.3 Return
Pressing the Enter button returns you to menu 8.2.0
R e t u r n
8 . 2 . 3
Menu 8.3.0 Current limiter
Settings and readings regarding the load monitor are
set on the submenus to this menu.
C u r r e n t l i m i t e r
8 . 3 . 0
Menu 8.3.2 Max. Elstep
The setting selected on the load monitor card (2) is
shown here knob (101).
7
M a x . E l s t e p
8 . 3 . 2
Menu 8.3.7 Return
Pressing the Enter button returns you to menu 8.3.0.
R e t u r n
8 . 3 . 7
Menu 8.3.1 Fuse size
The setting selected on the load monitor card (2) is
shown here knob (100).
1 6 A
F u s e s i z e
8 . 3 . 1
Menu 8.3.3 Current Phase 1
Shows the measured current from phase 1.
3 . 5 A
C u r r e n t P h a s e 1
8 . 3 . 3
Menu 8.3.4 Current Phase 2
Shows the measured current from phase 2.
3 . 3 A
C u r r e n t P h a s e 2
8 . 3 . 1
Menu 8.3.5 Current Phase 3
Shows the measured current from phase 3.
3 . 3 A
C u r r e n t P h a s e 3
8 . 3 . 5
Menu 8.3.6 Factor
The transfer value must be defined depending on the
current transformers used for the load monitor card.
This is done in this menu. The value is adjustable
between 100 and 900 in increments of 10. The setting
300 applies for the supplied current transformers.
3 0 0
F a c t o r
8 . 3 . 6
U
U
U
U
U
U
U
Other Adjustments