Control
37
SMO 10
Other Adjustments
Menu 8.2.0 Operating mode
Settings regarding auto mode can be made in the sub-
menus to this menu.
O p e r a t i n g m o d e
8 . 2 . 0
Menu 8.2.2 Wintertemp
The average outdoor temperature when the circulation
pump and immersion heater are blocked is selected
here. The value is adjustable between 0 and 30 °C.
1 5 ° C
W i n t e r t e m p
8 . 2 . 2
Menu 8.2.1 Summertemp.
The average outdoor temperature when the circulation
pump and immersion heater are blocked is selected
here. The value is adjustable between 0 and 30 °C.
2 0 ° C
S u m m e r t e m p .
8 . 2 . 1
U
U
U
Menu 8.1.0 Display settings
Settings concerning language and menu type are set
on the sub-menus to this menu.
D i s p l a y s e t t i n g s
8 . 1 . 0
Menu 8.1.1 Menu Type
The menu type is chosen here: Normal, extended or
service.
Normal, covers the normal user's needs.
Extended, shows all menus except the ser-
vice menus.
Service, shows all menus, returns to normal
30 minutes after the last button was pressed.
N o r m a l
M e n u T y p e
8 . 1 . 1
Menu 8.1.5 Return
Pressing the Enter button returns you to menu 8.1.0.
R e t u r n
8 . 1 . 5
Menu 8.1.2 Language
The required language is set here.
E n g l i s h
L a n g u a g e
8 . 1 . 2
Menu 8.1.4 Light Intensity
The light intensity in idle mode is set here. The value
is adjustable between 0 and 2. Idle mode occurs 30
minutes after the last button was pressed.
0=shutoff, 1=low, 2=average.
2
L i g h t I n t e n s i t y
8 . 1 . 4
Menu 8.1.3 Display Contrast
The display's contrast is set here. The value is
adjustable between 0 and 31.
1 0
D i s p l a y C o n t r a s t
8 . 1 . 3
N
U
N
N
U
N
U
S