16 List of Initial Settings
WF1967/WF1968
16-3
Sweep
Sweep type
Frequency
Frequency sweep range
1kHz to 10kHz
Phase sweep range
-90° to 90°
Amplitude sweep range
0.1Vp-p to 0.2Vp-p
DC offset sweep range
-0.1V to 0.1V
Duty sweep range
40% to 60%
Sweep time
0.1sec
Sweep mode
Continuous
Trigger source
Internal, 1sec
External trigger input polarity
Negative
Sweep function
One way, linear
Each marker value
5kHz, 0°, 0.15Vp-p, 0V, 50%
Stop level
Off, 0%
External control input
Disabled
Oscillation stop unit when gated single
Cycle
Synchronization/sub-output
Sweep synchronization, marker on
Burst
Burst mode
Trigger burst
Mark wave number
1.0
Space wave number
1.0
Trigger source
Internal, 10msec
External trigger input polarity
Negative
Trigger delay
0s
Stop level
Off, 0%
Oscillation stop unit at gate
Cycle
Synchronization/sub-output
Burst synchronization
Synclator
Synclator
Off
Trigger source
External
External trigger input polarity
Positive
2Channel Coordination (WF1968only)
Channel mode
Independent
Frequency difference
0Hz
Frequency ratio
1:1
Same value setting
Off
Summary of Contents for WAVE FACTORY WF1967
Page 2: ......
Page 3: ...MULTIFUNCTION GENERATOR WF1967 WF1968 Instruction Manual Operations DA00048287 002...
Page 4: ......
Page 10: ...WF1967 WF1968 vi...
Page 19: ...WF1967 WF1968 1 1 1 Overview 1 1 Features 1 2 1 2 Operating Principles 1 4...
Page 50: ...3 3 Cautions on Floating Ground Connection WF1967 WF1968 3 20 MEMO...
Page 156: ...4 9 Setting and Operation of Burst WF1967 WF1968 4 106 MEMO...
Page 206: ...7 9 Identifying Memory Space Required for Saving Arbitrary Waveforms WF1967 WF1968 7 14 MEMO...
Page 226: ...9 2 Performing Synchronization WF1967 WF1968 9 6 MEMO...
Page 262: ...13 6 Product Information Display Information WF1967 WF1968 13 4 MEMO...
Page 274: ...14 7 Suspected Failure WF1967 WF1968 14 12 MEMO...
Page 286: ...15 3 Performance Test WF1967 WF1968 15 12 MEMO...
Page 287: ...WF1967 WF1968 16 1 16 List of Initial Settings...
Page 326: ......
Page 328: ......
Page 329: ......