3 FST-2-Controller user interface
3.1 LC-Display and messages
10
FST-2_HB.EN12/05
3.1 LC-Display and messages
The LC-Display consists of four lines A, B, C and D with 20 digits each.
After switching on and during normal operation, the FST-2-Controller
displays the main screen.
Main screen
Line C has a special status. In normal mode (after switching on), it displays
status messages (see “Status messages in line C” on page 13). When
switching with key combination
S
+
¥
+
¤
it displays diagnostic
messages, see “Diagnostic messages in line C” on page 14.
Also see “Keypad functions” on page 32.
Line A
Safety circuit messages
in Line A
A
Maximum active state of the safety circuit
B
Active state or error
C
Status of the lift system / diagnostic message
D
Data for current drive mode
SAFETY CCT CLOSED
>AX< ###@###
00 13:06:56
Display
Description
SAFETY CCT CLOSED
The safety circuit is completely closed
(FST X14.1 & FST X14.2).
SFTY-CLOSED MISSING
The input “Safety circuit closed” has no power.
Possible reasons:
-
Terminal FST X14.1 has no power (normally
bridged with X14.2)
-
Relay K14 on the FST is faulty
DOOR LOCK B OPEN
The shaft door contact of door side B is
interrupted (FST X14.2 and X14.3).
DOOR LOCK A OPEN
The shaft door contact of door side A is
interrupted (FST X14.3 and X14.4).
DOOR A OPEN
The car door contact of door side A is
interrupted (FST X14.4 and X14.5).
DOOR B OPEN
The car door contact of door side B is
interrupted (FST X14.5 and X14.6).
DOOR C OPEN
The car door contact of door side C is
interrupted (FST X14.6 and X14.7).
MANUAL DOOR OPEN
A manual door contact is interrupted
(FST X14.6 and X14.7).
EMERGENCY END
SWITCH
The top emergency end switch of an hydraulic
lift is interrupted (FST X14.6 and X14.7).
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...