5 Menu tree
5.4 MAIN MENU – Config
116
FST-2_HB.EN12/05
Group settings –
ADM-Bus Mask-1
Allocation of the FST-2 to the individual bus cables of the
group in normal mode (see “ADM bus masks” on page 122
and GST Manual).
00 .. FF
Group settings –
ADM-Bus Mask-2
Allocation of the FST-2 to the individual bus cables of the
group in simplex mode (“separated group mode”, see GST
Manual).
00 .. FF
Anti nuisance –
Maximum Car Calls
Maximum permitted number of car calls acknowledged at a
time. This parameter helps prevent unnecessary drives
caused by car calls. A reasonable number is the specified
maximum number of passengers.
0 .. 63
Anti nuisance –
Stops w/o Exit
All car calls will be cleared if the photocell does not trigger for
the set number of stops. This parameter helps prevent
unnecessary drives caused by car calls.
0 .. 63
Anti nuisance –
Empty Car Sense
If the input “Empty Car Sense” is activated, no more car calls
will be accepted (see “FSM car control module” on page 53).
This parameter helps prevent unnecessary drives caused by
car calls. Only activate this function if the weight sensor is
equipped with an “Empty Car Sense” (Level-Empty) contact
and this contact is connected to the FSM!
YES
NO
Anti Nuisance –
Call Direction
All car calls against the current direction of travel will be
cleared when changing direction (e.g. when reaching a top or
bottom limit). This parameter helps “educate” passengers to
use the two button control correctly. Only activate when using
a two button control!
YES
NO
Anti nuisance –
Always Clear UP/DN
When approaching the target floor, landing calls in both
directions (up and down) will be deleted. This parameter helps
avoid unnecessary drives caused by “double calls” from one
passenger when using a two button control. Only activate
when using a two button control!
YES
NO
Car ventilator –
Control mode
Control modes for the Car ventilator (see “Car ventilator” on
page 122).
Switched Off
Manual ON/OFF
Off-Delay
AuOff-Delay
Car ventilator –
Vent. Off-Delay
Run-on time of the car ventilator in modes
Off-
Delay
and
AuOff-Delay
.
0 .. 250 sec
Car ventilator –
Output inverted
Invert the ventilator output on the FSM.
YES
NO
Car light –
Car light Off-Delay
Automatic deactivation of the car light after each drive after the
set time.
0 .. 9999 sec
Car light –
Monitoring
Monitoring the car light with a current sensor on the FSM. If
this parameter is activated, the operation of the car light is
monitored and the system will be shut down with
CAR
LIGHT FAILURE
if the car light fails (see “CAR LIGHT
YES
NO
Car light –
Evac. – Light Off
Switch off the car light after an evacuation drive.
YES
NO
Car panel module –
EAZ type
Position indicator code issued on FPM X4.
-
HEX: Binary code
-
1-of-N: Separate signal for each floor (only possible up to a
maximum of eight floors)
-
GRAY: Gray code
The initial value for the bottom floor can be set in
Bottom
Flr. Car
(see “Bottom Flr. Car” on page 114).
HEX
1-of-N
GRAY
Menu item
Description
Setting range
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...