5 Menu tree
5.4 MAIN MENU – Config
114
FST-2_HB.EN12/05
I/O Configuration –
I/O Flags –
Delay
Delay of inputs and outputs (see “Programmable inputs and
outputs” on page 147).
Depending on Bit1 of menu item
CTRL
, seconds or switching
operations must be set.
0 .. 9999
I/O Configuration –
I/O Flags –
MASK
System state that changes an input/output to active (see
“Programmable inputs and outputs” on page 147).
00000000 ..
FFFFFFFF
I/O Configuration –
I/O Flags –
CTRL
Flag control (see “Programmable inputs and outputs” on
page 147).
00 .. FF
I/O Configuration –
I/O Error –
ID
Error type to activate error output (see “Programmable inputs
and outputs” on page 147).
NO ERROR ...
CAR LIGHT FAILURE
I/O Configuration –
I/O Error –
CTRL
Configuration of error output (see “Programmable inputs and
outputs” on page 147).
00 .. FF
EAZ Configuration –
Use text
Enable user defined floor names.
-
YES: A two-digit floor name can be entered in
EAZ text
for each floor. This name will be used by the FST display and
by all LON position indicators.
-
NO: Floor names 0,1,2,.. will be used by the FST display and
by all LON position indicators.
YES
NO
EAZ Configuration –
EAZ text
Two-digit name for each floor (see
Use text
).
2-digit ASCII
EAZ Configuration –
Bottom Flr. Car
Initial value for the position indicator code issued on FPM X4.
-
0: Code starts at bottom floor with “00000000”.
-
1: Code starts at bottom floor with “00000001”.
The type of position indicator code can be set in
EAZ type
(see “Car panel module –” on page 116).
0 .. 1
EAZ Configuration –
Bottom Flr. Hall
Initial value for the position indicator code issued on ADM X3.
-
0: Code starts at bottom floor with “00000”.
-
1: Code starts at bottom floor with “00001”.
The type of position indicator code can be set in
ADM-EAZ
type
(see “ADM-EAZ Coding” on page 119).
0 .. 1
EAZ Configuration –
Target-Floor Car
Activation of position indicators at the deceleration point when
approaching a floor.
-
Show Target Floor: The target floor is displayed at the
deceleration point. As a consequence, floor names could be
skipped if the deceleration distance covers multiple floors.
-
Show Physical Floor: The target floor is displayed after
reaching the levelling position.
Show Target Floor
Show Physical Floor
EAZ Configuration –
LON-EAZ Type
Type of connected LON position indicators. Depending on the
type, the options set in
LON EAZ Config
have different
meanings (see description of the position indicator).
EAZ-256
EAZ-40/64
EAZ-VFD/LCD
EAZ Configuration –
LON-EAZ Number
LON position indicator selected for parametrising. Each
connected LON position indicator has a unique number (0 ..
255). If 255 is set here, the settings apply to all connected
LON indicators.
0 .. 255
EAZ Configuration –
LON-EAZ Config.
Options for the connected LON position indicators. Depending
on the
LON-EAZ type
, the options set here have different
meanings (see description of the position indicator).
00000000 ..
11111111
EAZ Configuration –
LON-EAZ Download
Transfer a configuration file from an inserted PC-Card to the
LON indicator selected in
LON-EAZ Number
.
³
YES
NO
Menu item
Description
Setting range
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...