4 Technical data
4.7 ADM landing call module
FST-2_HB.EN12/05
83
The landing call module is available with three different software versions:
-
ADM-S (“Single”) for single lifts
-
ADM-D (“Double”) for grouped lifts
-
ADM-E (“EAZ”) for position indicators
Terminals 1 .. 20 of terminal strip X3 are assigned differently depending on
the software version.
The values in the table are default factory settings. Functions of individual
systems can differ from those in the table. Please refer to the system
specific wiring diagrams.
Terminals for which more than one function is listed can be set to one of
these functions in the factory. The function “Direction” can be configured as
output for the direction of travel or as departure direction output in the FST-
2 menu.
The terminals labelled key switch 1 and 2 can be set to fire signal, smoke
detector, lift off and priority landing.
ADM-X3
Function ADM-S
Function ADM-D
Function ADM-E
1
+24V
+24V
+24V
2
Landing call UP
Landing call UP
3
Landing call DOWN
Landing call DOWN
4
Enable landing calls
Enable landing calls
Chime trigger
5
+24V
+24V
+24V
6
Occupied or out of operation
indicator
Occupied or out of operation
indicator (left lift)
Occupied or out of operation
indicator
7
-
Display “Special drive”
-
Chime trigger
-
Display “Special drive”
-
Chime trigger (left lift)
-
Special display 0 (“custom 0”
Floor display 5
8
Direction UP
Direction UP (left lift)
Direction UP
9
Direction DOWN
Direction DOWN (left lift)
Direction DOWN
10
GND
GND
GND
11
GND
GND
GND
12
Key switch 1
Key switch 1
13
Key switch 2
Key switch 2
14
-
Special display 0 (“custom 0”
-
Floor display 4
Floor display 4
15
+24V
+24V
+24V
16
Floor display 0
Direction DOWN (right lift)
Floor display 0
17
Floor display 1
Direction UP (right lift)
Floor display 1
18
Floor display 3
Occupied or out of operation
indicator (right lift)
Floor display 3
19
Floor display 2
Chime trigger (right lift)
Floor display 2
20
GND
GND
GND
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...