5 Menu tree
5.4 MAIN MENU – Config
FST-2_HB.EN12/05
115
EAZ Configuration –
IRT-code
Access code for the remote function. With indicator types
EAZ-VFD and EAZ-LCD, the FST-2-Controller can be
parametrised from the indicator using the FST-IRT infrared
remote control. This requires entering the access code set
here (see Quick Guide – FST-IRT Remote Control).
00000 .. 99999
EAZ Configuration –
Display Dimming
Dimming of LON display EAZ-256 when the car light is off to
reduce energy consumption. This function can be activated
separately for car and landing indicators.
-
00000000: Dimming function off.
-
00000001: Only car indicators are dimmed.
-
00000010: Only landing indicators are dimmed.
-
00000011: All indicators (car and landing) are dimmed.
00000000 ..
11111111
Chime functions –
Chime enabled
Chime sounds for car and/or landing calls.
YES
NO
Chime functions –
Chime duration
Impulse length of the chime trigger signal.
0 .. 5 sec
Chime functions –
Chime trigger
Distance of the car from the levelling position of the target floor
that triggers the chime.
0 .. 9999 mm
Chime functions –
Chime when in floor
The chime also sounds when the car is already at the target
floor and the car doors are closed if a landing call is placed.
YES
NO
Chime functions –
Landing chime
Chime sounds for landing and/or car calls.
Landing calls
L car calls
ID –
Lift ID
Identifies the FST-2-Controller in group operation.
The setting must correspond to the jumper settings (JK1, JK2
and JK3) on the FSM car control module (see “Jumper JT” on
page 55) and on the FPM car panel module (“Jumpers” on
page 40)! If this fails, the system will be shut down with
DRM-
CAR COMMS FAIL
(see “
page 177). Single lifts are always set to lift A.
A H
ID –
System ID
System location and identification of the FST-2-Controller for
modem, remote data transmission and PAM (LMS).
20-digit ASCII
ID –
NEW-Factory No.
NEW LIFT factory number of the FST-2-Controller (set in the
factory).
20-digit ASCII
ID –
Lift factory no.
Lift manufacturer’s factory number of the system.
20-digit ASCII
ID –
Project-Code
Code number of a project specific software version. Only
issued for special projects, do not change!
000000 ..
999999
Group settings –
GST menu
See GST Manual.
Group settings –
Lift ID
See
Lift ID
.
A H
Group settings –
Group member
Integrate FST-2-Controller in a GST Group Controller (see
GST Manual).
YES
NO
Group settings –
Group Floor Offset
Floor offset in relation to the lowest floor in the group (see GST
Manual).
0 .. 15
Group settings –
Flr Offset-Car
The value set in
Group Floor Offset
is the lowest floor
for the car position indicators (if not set, the value „0“ will be
used, see GST Manual).
YES
NO
Group settings –
Flr Offset-Landing
The value set in
Group Floor Offset
is the lowest floor
for the landing position indicators (if not set, the value „0“ will
be used, see GST Manual).
YES
NO
Menu item
Description
Setting range
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...