![NETGEAR ProSafe M4100-26-POE User Manual Download Page 605](http://html1.mh-extra.com/html/netgear/prosafe-m4100-26-poe/prosafe-m4100-26-poe_user-manual_1673614605.webp)
Utility Commands
605
ProSafe Managed Switch
rmon alarm
This command sets the RMON alarm entry in the RMON alarm MIB group.
Format
rmon alarm
alarm number variable sample interval sampling type
rising-threshold
value
falling-threshold
value
startup
rising/falling/rising-falling
owner
string
Mode
no rmon alarm
This command deletes the rmon alarm entry.
Format
no rmon alarm <alarm number>
Mode
rmon hcalarm
This command sets the rmon hcalarm entry in the High Capacity RMON alarm mib group.
Format
rmon hcalarm <alarm number> <variable> <sample interval>
<sampling type> rising-threshold high <value> low
<value> falling-threshold high <value> low <value>
startup <rising/falling/rising-falling> owner <string>
Mode
Global Config
Parameter
Description
Alarm Number
The Alarm number which identifies an Alarm.
Alarm Variable
The object identifier of the particular variable to be sampled. Only variables that resolve to an
ASN.1 primitive type of integer.
Sample Interval
The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds. The range is 0 to 2147483647. The default is 0.
Alarm Sample Type
The alarm sample type. The method of sampling the selected variable and calculating the
value to be compared against thresholds. Possible types are Absolute or Delta.
Alarm Rising
Threshold Value
The alarm rising threshold for the sample statistics.
Alarm Falling
Threshold Value
The alarm falling threshold for the sample statistics.
Alarm Startup
Alarm
The alarm that may be sent. Possible values are Rising Alarm, Falling Alarm or both.
Alarm Owner string
The alarm owner. The owner string associated with the alarm entry.
Global Config
Global Config