![NETGEAR ProSafe M4100-26-POE User Manual Download Page 189](http://html1.mh-extra.com/html/netgear/prosafe-m4100-26-poe/prosafe-m4100-26-poe_user-manual_1673614189.webp)
Switching Commands
189
ProSafe Managed Switch
Example: The following shows example CLI display output for the command.
(Switch) #show lldp med remote-device detail 1/0/8
LLDP MED Remote Device Detail
Local Interface: 1/0/8
Remote Identifier: 18
Capabilities
MED Capabilities Supported: capabilities, networkpolicy, location, extendedpse
MED Capabilities Enabled: capabilities, networkpolicy
Device Class: Endpoint Class I
Network Policies
Media Policy Application Type : voice
Vlan ID: 10
Priority: 5
DSCP: 1
Unknown: False
Tagged: True
Media Policy Application Type : streamingvideo
Vlan ID: 20
Priority: 1
DSCP: 2
Unknown: False
Tagged: True
Inventory
Hardware Rev: xxx xxx xxx
Serial Number
Shows the serial number of the remote device.
Manufacturer
Name
Shows the manufacture name of the remote device.
Model Name
Shows the model name of the remote device.
Asset ID
Shows the asset id of the remote device.
Sub Type
Shows the type of location information.
Location
Information
Shows the location information as a string for a given type of location id
Device Type
Shows the remote device’s PoE device type connected to this port.
Available
Shows the remote port’s PSE power value in tenths of a watt.
Source
Shows the remote port’s PSE power source.
Priority
Shows the remote port’s PSE priority.
Required
Shows the remote port’s PD power requirement.
Source
Shows the remote port’s PD power source.
Priority
Shows the remote port’s PD power priority.
Term
Definition