Utility Commands
535
ProSafe Managed Switch
no logging email urgent
This command resets the urgent severity level to the default value.
Format
no logging email urgent
Mode
logging email message-type to-addr
This command configures the email address to which messages are sent. The message
types supported are
urgent
,
non-urgent
, and
both
. For each supported severity level,
multiple email addresses can be configured. The
to-email-addr
variable is a standard email
address, for example
.
Format
logging email message-type {urgent |non-urgent |both}
to-addr <
to-email-addr
>
Mode
no logging email message-type to-addr
This command removes the configured to-addr field of email.
Format
no logging email message-type {urgent |non-urgent |both}
to-addr <
to-email-addr
>
Mode
logging email from-addr
This command configures the email address of the sender (the switch).
Default
Format
logging email from-addr <
from-email-addr
>
Mode
no logging email from-addr
This command removes the configured email source address.
Format
no logging email from-addr <
from-email-addr
>
Mode
Global Config
Global Config
Global Config
Global Config
Global Config