![NetApp NearStore R100 Hardware And Service Manual Download Page 50](http://html1.mh-extra.com/html/netapp/nearstore-r100/nearstore-r100_hardware-and-service-manual_1669958050.webp)
40
Connecting an R100 chassis to an Ethernet network
Ethernet cabling
requirements
The following table lists the cabling requirements for Ethernet connections.
Note
Do not exceed the maximum cable length specification.
Ethernet port
Cabling requirements
10Base-T/
100Base-TX
Category 3 (10Base-T only) or 5 (10Base-T/100Base-
TX) unshielded twisted-pair (UTP) cable with RJ-45
connectors
100Base-TX/
1000Base-T
Category 5 unshielded twisted-pair (UTP) cable with
RJ-45 connectors
1000Base-SX
fiber
Type of cable
Max. distance
50 micron multimode fiber optic cable
with SC connector
550m
62.5 micron multimode fiber optic
cable with SC connector
220m