138
Boot error messages
Drive %s.%d not
supported
%s—The adapter slot number;
%d—The disk ID number. The
system detects an unsupported
disk drive.
Yes
1. Remove the drive
immediately or the system
drops down to the PROM
monitor within 30 seconds.
2. Check the System
Configuration Guide at
http://now.netapp.com
to
verify support for your disk
drive.
FC-AL loop down,
adapter %d
The system cannot detect the
FC-AL loop or adapter.
Yes
1. Identify the adapter by
entering the following
command:
storage show adapter
2. Turn off the power on the
chassis and verify that the
adapter is properly seated in
the expansion slot.
3. Verify that all Fibre Channel
cables are connected.
Boot error message
Explanation
Fatal?
Corrective action