![NetApp NearStore R100 Hardware And Service Manual Download Page 152](http://html1.mh-extra.com/html/netapp/nearstore-r100/nearstore-r100_hardware-and-service-manual_1669958152.webp)
142
All other error messages
Disk hung during swap
A disk error occurred as you
were hot swapping a disk.
Yes
1. Disconnect the disk shelf
from the power supply.
2. Wait 15 seconds to allow
all disks to spin down.
3. Reconnect the power
source to the disk shelf.
4. Restart the system by
entering the following
command:
boot
Error dumping core
The system cannot dump core
during a system crash and
restarts without dumping core.
Yes
Report the problem to Network
Appliance Technical Support.
Panicking
The system is crashing. If the
system does not hang while
crashing, the message
Dumping
core
appears.
Yes
Report the problem to Network
Appliance Technical Support.
System too hot
The temperature sensor indicates
that the system temperature is
too high.
Yes
Verify that the ventilation holes
on the top cover of the system
are not blocked. If the
ventilation holes are not
blocked and the problem
persists, contact Network
Appliance Technical Support
for help.
Error message
Explanation
Fatal?
Corrective action