Closing the PCB carrier
Closing the PCB carrier
Closing the PCB
carrier
To close the PCB carrier, follow these steps.
Step
Action
1
If you removed the PCB carrier, insert the carrier slide rails evenly
and slowly into the slide rails using both hands to support the PCB
carrier. There should be no resistance.
Caution
The carrier slide rails must align with the ball bearings along the
chassis slide rails; otherwise the PCB carrier does not go in and the
slide rails could be bent permanently.
2
Carefully push the PCB carrier into the chassis.
If the PCB carrier is locked in position, press inward on the carrier
tabs on each carrier slide rail while pushing the PCB carrier into the
chassis.
3
Tighten and then torque the eight thumbscrews on the back panel of
the PCB carrier 8 to 10 in.-lbs to prevent access without a tool.
4
Reconnect any adapter cables you removed.
5
Reconnect and turn on the power to the chassis.
6
Interrupt the boot process by pressing the Delete key during the
memory test.
7
Run diagnostics by entering the following command at the
ok>
prompt:
sys-diag
See the Diagnostics Guide for more information.
8
Run the specific diagnostics that apply to the unit you installed or
replaced.
Summary of Contents for NearStore R100