Program
81
Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level
IN
Description
Use
Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
to define the various basic
timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Input Data
Layer 3 Timer Type Number
1~5
Item No.
Item
Description
Input Data
Default
01
T301
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
ALERT message is received.
0, 180~254 (sec)
180 (sec)
02
T302
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is sent. Timer is also restarted
when INFO is received.
1~254 (sec)
15 (sec)
03
T303
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent.
1~254 (sec)
4 (sec)
04
T304
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is received. Timer is also re-
started when INFO is received.
0~254 (sec)
30 (sec)
05
T305
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC without progress No. 8 is sent.
1~254 (sec)
30 (sec)
06
T306
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC with progress indicator No. 8 is sent.
This timer is valid for Network side use
only.
0~254 (sec)
30 (sec)
07
T307
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND ACK is sent. This timer is valid
only for Network side use only.
1~254 (sec)
180 (sec)
08
T308
Specifies the timer value in 1/100ths of a
second of the timer to be started when
REL is sent.
1~254 (sec)
4 (sec)
09
T309
Specifies the timer value in 1/100ths of a
second upon data link disconnection.
1~254 (sec)
90 (sec)
10
T310
Specifies the timer value in 1/100ths of a
second of the timer to be started when
CALL PROC is sent.
0~180 (sec)
180 (sec)
11
T312
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast
data link. This timer is only valid for Net-
work side use only.
1~254 (sec)
6 (sec)
12
T313
Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
1~254 (sec)
4 (sec)
13
T314
Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
1~254 (sec)
4 (sec)
Issue 0.1
SL1000
Program 81 : Basic Hardware Setup for Trunk
2-420
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...