Program
90
Alarm
No.
Alarm
Sta-
tus
64
1
0
VoIPDB
LAN Link
Error.
The link of LAN of
VoIPDB came off.
1
LAN cable
is defec-
tive.
2
Connected
HUB bro-
ken.
3
Defect
CPU.
1
Confirm LAN
connector
and wiring.
2
Check with
maker on
uncertain
points.
When the
connection
returns nor-
mally, the
error is
recovered.
ERR
REC
65
0
0
VOIPDB
trouble
information.
When DSP of
VoIPDB notifies
Error.
VoIPDB. defective.
1
Possibility of
defective
hardware.
2
Check with
maker on
uncertain
points.
WAR
66
2
0
SIP exten-
sion
License
Error.
More than the num-
ber of licenses to
which the SIP exten-
sion terminal was
turned on at
REGISTER.
• Wrong
number of
licenses.
1
Confirm the
number of
licenses for
SIP extension
terminals.
2
Check with
maker on
uncertain
points.
When the
number of
registration
of SIP ex-
tension
terminals
falls below
the number
of licenses.
WAR
67
0
0
SIP illegal
Packet
received
The system received
illegal packet.
A client or network
was illegal state.
Check with maker on
uncertain point, when
happening frequently
when operating it.
INF
68
2
0
VoIP DSP
All Busy
Alarm
1
Provides
alert when
all DSP re-
sources are
being used.
2
Used to
troubleshoot
or alerting
when up-
grade is
needed.
Not enough DSP
resources in
system.
Install PZ-VMDB with
more DSP resources.
Conditions
• The entire terminal that has an Alarm Display setting can be set at PRG90-50-01.
• System Alarm Type is shown despite the setting done at 90-10-01. If multiple Alarm Display Set-
ting is set, only one highest priority alarm will be shown on a LCD Display.
• The priority level (highest -> lowest): Alarm 55 > Alarm 7 > Alarm 5 > Alarm 30 > Alarm 8 > Alarm
52> Alarm 29 > Free Demo License Period.
Feature Cross Reference
None
Issue 0.1
SL1000
Program 90 : Maintenance Program
2-504
Recovery
Type
Re-
port
Name
Content of Alarm
Cause
Action
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...