Program
22
Item No.
Input Data
Description
Default
01
Received Number
This is the received DID digits.
Maximum eight digits
(0-9,
*
, #, @)
(0-9,
*
, #)
See Default Value
02
T
arget Number
Enter the destination number to
which the DID number is sent.
Maximum 36 digits
(0-9,
*
, #, @)
See Default Value
03
DID Name
This is the name that is assigned
to the DID digits when it rings
the extension.
Maximum 12 characters
No Setting
04
Transfer Operation Mode
0 = No Transfer
1 = Busy
2 = No Answer
3 = Busy/No Answer
0
05
T
ransfer Destination
Number 1
0 =No set
1-25 =Incoming Rin Group
101 = Not used
102 =VMI
103 =Not used
201-232 =Department Group
400 =DUD
401 =DISA
501-599 =DISA
(VRS Message No.)
1000-1999=
Common ABB Dial (000-999)
0
06
Transfer Destination Number 2
400 - Allow the outside party to
dial a different extension number
in the translation table (for
example, ring no answer to a
dialed number, the caller then
hears a dial tone, allowing them
to enter another Valid Extension
Number).401 - Provide the caller
with DISA dialing options
(requires using the DISA
password).
This applies to 22-
11-05 and
22-11-06.
0
07
Call Waiting
PRG 20-09-07 overrides this
setting.
0 = Disable (No)
1 = Enable (Yes)
0
08
Maximum Number of DID Calls
0~126 (0 =No limit)
0
09
Music on Hold Source
0 = IC/MOH Port
1 = BGM Port
2 = ACI Port
0
10
ACI Music Source Port
When a sound source type is 2 in above : (0~6)
0
11
Incoming Ring Group Transfer
Enable (1) or disable (0) each
conversation tables ability to
follow the Ring Group program-
ming defined in Program
22-12-01 : DID Intercept Ring
Group.
If Program 22-11-05 : DID Trans-
lation Number Conversion,
Transfer Destination Number 1
and Program 22-11-06 : DID
Translation Number Conversion,
Transfer Destination Number 2
are set, the priority of transfer-
ring is in this order: Program
22-11-05 then Program 22-11-06
then if Program 22-11-11 is
enabled, Program 22-12-01.
0 = Disable (Caller will hear Ringback)
1 = Enabled (Go to normal ring)
1
Default
The default value of PRG22-11-01/PRG22-11-02 is shown as below.
Conversion Table
Received number
Target number
1
00
200
Issue 0.1
SL1000
Programming Manual
2-235
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...