Program
81
Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Level
IN
Description
Use
Program 81-08 : T1 Trunk Timer Setup
to define the basic timer setting of each T1 Trunk type.
Input Data
Item
Name
Input Data
Default
01
Answer Signal Detection Time (Loop)
1~250 (4 ms ~ 1000 ms)
15
60 ms
02
Answer Signal Detection Time (Ground)
1~250 (4 ms ~ 1000 ms)
15
60 ms
03
Answer Signal Detection Time (DID)
1~250 (4 ms ~ 1000 ms)
15
60 ms
04
Answer Signal Detection Time (E&M)
1~250 (4 ms ~ 1000 ms)
15
60 ms
05
Answer Signal Detection Time (OPX)
1~250 (4 ms ~ 1000 ms)
15
60 ms
06
Clear Signal Detection Time (Loop)
1~255 (100 ms ~ 25500 ms)
6
600 ms
07
Clear Signal Detection Time (Ground)
1~255 (100 ms ~ 25500 ms)
6
600 ms
08
Clear Signal Detection Time (DID)
1~255 (100 ms ~ 25500 ms)
6
600 ms
09
Answer Signal Detection Time (E&M)
1~255 (100 ms ~ 25500 ms)
6
600 ms
10
Clear Signal Detection Time (OPX)
1~255 (100 ms ~ 25500 ms)
6
600 ms
11
Ringing Signal Detection Time (Loop)
1~250 (8 ms ~ 2000 ms)
10
80 ms
12
Ringing Signal Detection Time (Ground)
1~250 (8 ms ~ 2000 ms)
10
80 ms
13
Ringing Signal Detection Time (DID)
1~250 (8 ms ~ 2000 ms)
10
80 ms
14
Ringing Signal Detection Time (E&M)
1~250 (8 ms ~ 2000 ms)
10
80 ms
15
Ringing Signal Detection Time (OPX)
1~250 (8 ms ~ 2000 ms)
10
80 ms
16
Ringing Signal Stop Detection Time (Loop)
1~255 (100 ms ~ 25500 ms)
50
5000 ms
17
Ringing Signal Stop Detection Time
(Ground)
1~255 (100 ms ~ 25500 ms)
50
5000 ms
18
Ringing Signal Stop Detection Time (DID)
1~255 (100 ms ~ 25500 ms)
50
5000 ms
19
Ringing Signal Stop Detection Time (E&M)
1~255 (100 ms ~ 25500 ms)
50
5000 ms
20
Ringing Signal Stop Detection Time (OPX)
1~255 (100 ms ~ 25500 ms)
50
5000 ms
21
Loop Current Detection Time (Loop)
1~250 (4 ms ~ 1000 ms)
40
160 ms
Issue 0.1
SL1000
Programming Manual
2-423
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...