Program
10
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
Level
SA
Description
Use
Program 10-23 : SIP System Interconnection Setup
to determine if the system is intercon-
nected and define the IP address of another system, call control port number and alias address for
SL1000 system interconnection.
Input Data
System Number
001~1000
Item No.
Item
Input Data
Default
01
System
Interconnection
0 = No (Disable)
1 = Yes (Enable)
0
02
IP Address
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
03
Call Control Port
1~65535
1720
04
Dial Number
Up to 12 digits (0~9)
Not Set
Conditions
None
Feature Cross Reference
None
Issue 0.1
SL1000
Program 10 : System Configuration Setup
2-28
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...