Program
47
Program 47 : InMail
47-01 : InMail System Options
Level
IN
Description
Use
Program 47-01 : InMail System Options
to set up the InMail system-wide options.
Input Data
t
l
u
a
f
e
D
a
t
a
D
t
u
p
n
I
m
e
t
I
.
o
N
m
e
t
I
02
InMail Master Name
(MasterName)
The CPU must be reset for a change to this
program to take effect.
Use this option to modify the name for all InMail
ports. The system briefly displays this name when
a display multiline terminal user calls a Voice Mail
port (either by pressing
Message
, their voice mail
key, or by dialing the master number). You should
always end the name with the
##
characters. The
system substitutes the port number for the last #.
Using the default name
InMail ##
, for example, the
telephone display shows
InMail #1
when calling
port 1.
Up to 12 characters
InMail
##
(The system substi-
tutes the port number
for the
#
when calling
the port).
03
Subscriber Message Length
(Subs Msg Length)
Use this option to set the maximum length of
recorded messages for:
• Subscriber Mailbox users dialing
RS
to
record and send a message.
• Extension users leaving a message in a
Subscriber Mailbox.
• Outside Automated Attendant callers
accessing a mailbox via a GOTO command
and then dialing
RS
to record and send a
message.
• Subscriber Mailbox Greetings.
• Announcement Messages.
• Call Routing Mailbox Instruction Menus.
The length of a Conversation Re-
cord is 10 times the Subscriber
Message Length. Since the Conver-
sation Record time cannot exceed
4095 seconds, any setting in Subsc-
riber Mes-sage Length larger than
409 has no effect on the length of
recorded conversations.
0
2
1
)
c
e
s
(
5
9
0
4
~
1
04
Non-Subscriber Message Length
(Mbox Msg Length)
Use this option to set the maximum length of
recorded messages for:
• Automated Attendant callers leaving a
message or Quick Message in a Subscriber
Mailbox.
• Outside callers transferred by an extension
user to a Subscriber Mailbox.
0
2
1
)
c
e
s
(
5
9
0
4
~
1
05
Message Backup/Go Ahead Time
(Msg Bkup/Adv Time)
Use this option to set the backup/ go ahead time.
This time sets how far InMail backs up when a
user dials
B
while listening to a message. This
interval also sets how far InMail jumps ahead
when a user dials
G
while listening to a message.
5
)
c
e
s
(
0
6
~
1
Issue 0.1
SL1000
Program 47 : InMail
2-354
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...