Program
84
Item No.
Item
Input Data
Default
24
RTP Echo Canceller Tail Length
1 = 32 ms
2 = 48 ms
3 = 64 ms
4 = 80 ms
5 = 96ms
6 = 112ms
7 = 128ms
7
25
RTP Echo Canceller Default ERL
Level
0-6 (-9 dB ~ 9 dB)
0 = -9 dB
1 = -6 dB
2 = -3 dB
:
5 = 6 dB
6 = 9 dB
5
26
RTP Echo Canceller Echo Type
0 = Disable
1 = Line Echo Canceller
2 = Acoustic Echo Canceller
0
27
RTP Max ERLE
0-10 (24 ~ 54dB)
0 = 24 dB
1 = 27 dB
:
9 = 51 dB
10 = 54 dB
2
28
RTP Tx Level Control
0 = Disable
1 = TxLevelControl mode
2 = TxAutomaticLevelControl mode
3 = HLC
0
29
RTP Tx Level Control Level
0-16 (-24 ~ 24 dB)
0 = -24 dB
1 = -21 dB
2 = -18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
8
30
RTP Tx AutomaticLevelControl
Level
0-12 (-42 dBm ~ -6 dBm)
0 = -42 dBm
1 = -39 dBm
:
7 = -21 dBm
:
11 = -9 dBm
12 = -6 dBm
7
31
RTP Tx HLC Threshold
0-42 (-42 dBm ~ 0 dBm)
0 = -42 dBm
1 = -41 dBm
:
42 = 0 dBm
42
32
RTP Tx Gain Compression mode
0 = Disable
1 = Enable
0
33
RTP Tx Gain Compression
Threshold
0-42 (-42 dBm ~ 0 dBm)
0 = -42 dBm
1 = -41 dBm
:
42 = 0 dBm
42
34
RTP Rx Level Control
0 = Disable
1 = Rx Level Control mode
2 = Rx Automatic Level Control
Flag
0
Issue 0.1
SL1000
Program 84 : Hardware Setup for VoIP
2-486
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...