Program
32
Program 32 : Door Box and Sensor Setup
32-02 : Door Box Ring Assignment
Level
SA
Description
Use
Program 32-02 : Door Box Ring Assignment
to assign the extension which rings when a caller
presses the associated Door Box call button.
The Door Box feature is called Door Phone when programming via WebPro and using a multiline termi-
nal.
Input Data
Door Box Number
1~8
Day/Night Mode
1~8
Item No.
Door Box Ring Group Number
Extension Number
Default
01
01~32
Maximum four digits
Door Box Ringing Member 1 :
200
Other : No Setting
Conditions
None
Feature Cross Reference
• Door Box
Issue 0.1
SL1000
Programming Manual
2-305